Agilent Manuals (Industrial)

Agilent high-speed Separating high-throughput (RRHT) And column ChromSword Software makeuse And Agilent 1200SL Of artemisinin by the system analysis Manual

This document describes a simple isocratic method for analyzing artemisinin using the Agilent 1200SL system with high-speed separation high-throughput (RRHT) columns and ChromSword software. The method development was automated using the ChromSword software, which helped in selecting the optimal column. By utilizing a fully automated unmanned method development program, the analysis time was significantly reduced.

File format: PDF Size:371 KB

Agilent immune And sedimentation Agilent High Sensitivity Protein 250 Assay: Agilent 2100 High sensitivity detection specificity of proteins by Bioanalyzer Manual

This document introduces a new method that combines immunoprecipitation with Agilent High Sensitivity Protein 250 assay on Agilent 2100 Bioanalyzer to detect proteins on a microchip with high specificity and sensitivity. This method is useful for protein expression and purification research in fields such as pharmaceuticals, biotechnology, and specialized research institutions. Compared to Western blotting, this method offers more reliable results, better accuracy, improved productivity, reduced antibody costs, and lower reagent consumption.

File format: PDF Size:349 KB

Agilent 7890A/5975A GC/MSIn the system Automatic Backflush Manual

This application note describes some of the key points and advice for using the auto-backflush function on the Agilent 7890A/5975A GC/MS system, and provides an example of how to set up and use backflushing for monitoring biomarkers in crude oil.

File format: PDF Size:680 KB

Agilent Refinery gas (RGA) GC analysis Manual

This application note describes a 6-minute Agilent 7890A GC-based refinery gas analysis (RGA) system. The system consists of 7890A GC, three detectors (TCD, ECD and FID), five valves, a 10-port valve and seven columns. The system can fully analyze nC6 and below hydrocarbons and permanent gases, including nitrogen, hydrogen, oxygen, carbon monoxide and carbon dioxide, within 6 minutes.

File format: PDF Size:157 KB

Agilent Of refinery gas GC analysis Manual

This application note describes a method for high-resolution analysis of refinery gas using an Agilent 7890A GC. The method uses a triple detector configuration, including an FID, a TCD (using nitrogen or argon as the carrier gas) and a TCD (using helium as the carrier gas). This method allows analysis of a variety of components, including permanent gases, hydrocarbons and sulfur compounds, in 6 minutes.

File format: PDF Size:491 KB

Agilent ZORBAX StableBond SB-C18 LC The column makeuse And LC/MS Of its metabolites in plasma oxycodone by the system analysis Manual

This application note describes a method for analyzing oxycodone and its metabolites (noroxycodone, oxymorphone, and noroxymorphone) in plasma using high-performance liquid chromatography/mass spectrometry (HPLC/MS) and the Agilent ZORBAX Rapid Resolution High Throughput (RRHT) StableBond SB-C18 column for chromatographic separation. The method employs an ammonium acetate/acetonitrile gradient and detection by electrospray positive ionization mode mass spectrometry. Spiked human plasma samples are subjected to solid-phase extraction prior to HPLC/MS analysis. The method provides fast, efficient analysis with minimal solvent consumption, which increases productivity, and good linearity (R2 > 0.9900) and reproducibility (less than 10% difference between replicate analyses) for all compounds.

File format: PDF Size:191 KB

Agilent Drinking water analysis In Agilent 7700x ICP-MS Superiority of Manual

The Agilent 7700x ICP-MS is an instrument for analyzing trace metals in drinking water. It features the third generation Octopole Reaction System (ORS3) technology and improved Helium (He) collision mode, which allows for the removal of polyatomic ion interferences without the need for complex interference correction equations. This results in easier method development, lower detection limits, and shorter analysis time.

File format: PDF Size:281 KB

Agilent Off-flavor analysis In SPME-GC/MS Use of beauty multivariate analysis technology Manual

This article introduces a method for analyzing the odor of mineral water using solid phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS). The samples were analyzed using multivariate analysis software (Mass Profiler Professional), and 26 components with statistically significant differences were selected. This method can extract components that are difficult to confirm through chromatogram comparison, making it useful for identifying the causes of odor.

File format: PDF Size:300 KB

Agilent GC/MS Simultaneous component of 85 water quality regulations Pesticides analysis Manual

This application note describes a method for simultaneous determination of 85 water quality regulated pesticides using Agilent GC/MS, including 76 organophosphorus pesticides, including 9 oxidation products and 5 oxidation products of fenitrothion. At a standard solution of 5 ppb, all pesticides can be detected, and the RSD (n=6) of the internal standard is 2.1-16.8%.

File format: PDF Size:208 KB

Agilent 7890 GC/5975C TAD Manual

This document describes the features of the new PP&TT system Stratum, including low dead volume, high sensitivity analysis, and low carryover. When combined with Agilent's 7890A/5975CTAD system and CFT technology, efficient analysis can be achieved.

File format: PDF Size:400 KB

Agilent G2565CA Scanner per microarray Guide

This document is a user guide for Agilent Technologies' Agilent G2565CA Scanner with SureScan high-resolution technology. It is intended for research purposes only and not for diagnostic procedures.

File format: PDF Size:5784 KB

Agilent G1978A Sorgente multimode per G1946/G1956 LC/MSD Guide

This manual describes the configuration of the Agilent G1978A Multi-mode Source.

File format: PDF Size:45925 KB

Agilent Italian Version - Operational Qualification for HPLC Manual

This document introduces Agilent Enterprise Edition software, which can perform functional and performance tests on analytical instruments and generate test reports.

File format: PDF Size:28 KB

Agilent Italian version - Remote Advisor Reports - Included in Agilent Advantage Bronze Support Agreements - Technical Overview Manual

This document describes the features and technical characteristics of the Remote Advisor reports included in the Agilent Advantage Bronze contracts, as well as how these reports help users make decisions to improve the effectiveness of their instruments.

File format: PDF Size:199 KB

Agilent Italian version- Cary 60 UV-Vis Specifications Manual

The Agilent Cary 60 is a UV-Vis spectrophotometer produced by Agilent. It uses a classic Cary optical design with a Czerny-Turner monochromator. The spectral range is 190-1100nm, the resolution is less than 1.5nm, and a single xenon light source is used with a lifetime of up to 10 years. It has two silicon detectors, multiple layers of quartz optical elements, a scanning speed of up to 24000nm/min, a maximum speed of 80 points/second for time events, and a grid shift in non-measurement. It is immune to external scattered light and is fully controlled by a PC via Windows and a USB port. It has GLP and CFR 21 Part 11 software for complete instrument validation in accordance with all pharmacopoeias.

File format: PDF Size:66 KB

Agilent Italian version - Consumables Supplies Required for Repair Manual

When your system needs repairs, it’s best to have complete coverage that includes a supply of the spare parts and consumables not covered by basic repair services. That’s why the Agilent Advantage Bronze, Silver and Gold services include the Optional Repair Parts and Consumables. The Optional Repair Parts and Consumables option covers the cost of all replacement parts or consumables needed by the technician to diagnose issues and repair your systems. Since all “Advantage” services also cover travel costs, labor and parts, you can be confident that you’re covered for all your repair costs. You’ll get all original Agilent parts and consumables regardless of the number of repairs or the quantity of products required to return your system to normal operation. Even if you only have one repair, services that include all the spare parts and consumables will easily pay for the difference in price over services that don’t.

File format: PDF Size:75 KB

Agilent Guida alla scelta delle colonne Zorbax Agilent per HPLC Manual

This document mainly introduces the ZORBAX series products, including ZORBAX StableBond, ZORBAX SB-Aq, ZORBAX Rx, ZORBAX Eclipse XDB, ZORBAX Bonus-RP, ZORBAX Extend-C18, other ZORBAX HPLC analytical columns and ZORBAX CombiHT, ZORBAX Rapid Resolution 3.5 µm, MicroBore and Capillary.

File format: PDF Size:19548 KB

Brands



Products